Rockwell Hardness Testing Machine HR-620B main unit | 810-526-11
Описание
With innovative design and functionality that enables a wide variety of measurements, the HR-600 Series delivers hardness testing that defies conventional thinking. Go above and beyond High-End CNC Rockwell Hardness Testing Machine, providing a fully automatic Rockwell hardness test sequenceThe HR-600 Series combines the functionality of several previous models:Rockwell hardness testing, Brinell hardness testing, Brinell and Vickers depth measurement hardness testing and hardness testing of plastic materials. Supporting all test types in a single machine, this new series expands the range of available measurements.With its high-resolution scale load cell developed uniquely by Mitutoyo that allows for high-precision test load feedback control and state-of-the-art design that delivers both aesthetics and usability on the ground, the new HR-600 Series enables hardness testing that defies conventional thinking.New design with functional beauty With a table for mounting workpieces and head with vertical mobility, the HR-600 Series is built for operability and usability. Its new design is highly focused on end-user usability, and the entire product structure has been inventively modified for functional beauty — a true embodiment of Mitutoyo’s pioneering spirit.Attention:* requires optional accessories** more on request*** can be enhanced with additional accesories
Особености
A főegység méretei | Külső méretek 428(Sz) × 837(Mé) × 935(Ma) mmKijelző egység külső méretei 191(Sz) × 71(Mé) × 147(Ma) mm (optional)Főegység tömege 205kgTápegység AC100V, 120V, 220V, 240V Automata választásTápkábel nem alaptartozékÜzemi hőmérséklet 5-40 °CPáratartalom 55-65% (kondenzáció nélkül) |
Abmaße Hauptgerät | External dimensions 428(W) × 837(D) × 935(H) mmExternal dimensions display unit 191(W) × 71(D) × 147(H) mm (optional)Mass main unit 205kgPower supply AC100V, 120V, 220V, 240V Auto-selectionPower cord not includedOperation temperature 5-40 °CHumidity 55-65% (without dew condensation) |
Alkalmazható vizsgálati módszerek és szabványok | Rockwell, Szuper-Rockwell (EN ISO 6508, ASTM E-18, JIS B7726)Golyóbenyomásost vizsgálat műanyagokon (EN ISO 2039-1)Műanyag vizsgálat (EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Rockwell Alfa teszt (ASTM D785 B)Brinell, csak lenyomat (EN ISO 6506, ASTM E-10, JIS B7724)HBT (VDE/VDI 2616 - nem szabványos)HVT (VDE/VDI 2616 - nem szabványos) |
Applicable test methods and standards | Rockwell, Rockwell Superficial (EN ISO 6508, ASTM E-18, JIS B7726)Ball indentation test on plastic materials (EN ISO 2039-1)Plastic test (EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Rockwell Alpha test (ASTM D785 B)Brinell, Indentation only (EN ISO 6506, ASTM E-10, JIS B7724)HBT (VDE/VDI 2616 - non standard)HVT (VDE/VDI 2616 - non standard) |
Arbetsstyckets dimensioner | Contact unit contact area ** 18x4mmMinimum inside radius of workpiece 25mmMinimum inside Ø of workpiece 400mmMinimum outside radius of workpiece 20mmBasic test surface 200 x 200mm ***Anvil adaption Ø 10mm / Ø 19mm (optional)Max. specimen height (reduced by addiing accessories and X-axis) 250mmX-axis option (optional)Z-axis height (Max. specimen heigh)t 250mmZ-axis height with X-axis added (Max. specimen height) 165mmY-axis range 160mmThroat depth 220mmMax. specimen weight 100kgMax. specimen weight with X-axis mounted 50kgMax. speed Y 48mmMax. speed Z 10mm/sec |
Ball Indentation plastic test | HB 49N; HB 132N; HB 358N; HB 961N |
Brinell | HBW 1/10; HBW 2.5/6.25; HBW 5/25; HBW 10/100; HBW 1/30; HBW 2.5/15.625; HBW 5/62.5; HBW 2.5/31.25; HBW 5/125; HBW 2.5/62.5; HBW 2.5/187.5 |
Brinell Depth Measurement | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Brinell dieptemeting | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Brinell djupmätning | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Brinell mélységmérés | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Dimensioni funzionali | Contact unit contact area ** 18x4mmMinimum inside radius of workpiece 25mmMinimum inside Ø of workpiece 400mmMinimum outside radius of workpiece 20mmBasic test surface 200 x 200mm ***Anvil adaption Ø 10mm / Ø 19mm (optional)Max. specimen height (reduced by addiing accessories and X-axis) 250mmX-axis option (optional)Z-axis height (Max. specimen heigh)t 250mmZ-axis height with X-axis added (Max. specimen height) 165mmY-axis range 160mmThroat depth 220mmMax. specimen weight 100kgMax. specimen weight with X-axis mounted 50kgMax. speed Y 48mmMax. speed Z 10mm/sec |
Dimensioni unità principale | External dimensions 428(W) × 837(D) × 935(H) mmExternal dimensions display unit 191(W) × 71(D) × 147(H) mm (optional)Mass main unit 205kgPower supply AC100V, 120V, 220V, 240V Auto-selectionPower cord not includedOperation temperature 5-40 °CHumidity 55-65% (without dew condensation) |
Dimensions de l'unité principale | Dimensions externes 428 (L) x 837 (l) x 935 (h) mmDimensions externes afficheur 191 (L) x 71 (l) x 147 (h) mmMasse unité principale 205 kgAlimentation 100V, 120V, 220V, sélection automatique 240VCordon d'alimentation non inclusTempérature de fonctionnement 5-40 ° CHumidité 55-65% (sans condensation) |
Dimensions fonctionnelles | Surface de contact ** 18x4mm Rayon intérieur minimum de la pièce 25 mm Ø minimum intérieur de la pièce 400mm Rayon extérieur minimum de la pièce 20 mm Surface d'essai de base 200 x 200 mm *** En option Touche Ø 10 mm (série)/Ø 19 mm (en option)Max. hauteur pièce (réduit par ajout accessoires et axe X) 250mm Axe X en optionHauteur de l'axe Z (Hauteur maximale pièce) 250mm Hauteur de l'axe Z avec l'axe x ajouté (Hauteur maximale spécimen.) 165mm Capacité axe Y 160 mmProfondeur de col 220 mm Poids max. pièce 100 kg Poids max. pièce avec l'axe X monté 50 kgVitesse Max. Y 48 mmVitesse Max. Z 10 mm/sec |
Fonctionnalité | 5,7" écran tactilemmmm/inch (option)Résolution HR 0,01Plage de force de test 1-250KG, 9,8-2450NForce d'essai de commutation par logicielContrôle de la force d'essai en temps réelCycle de test entièrement automatiqueGénération de la force d'essai motoriséeAxe Z MotoriséEclairage LED atelierRS-232C Digimatic, interface USB2.0Transfert de données de clé USBTest capacité Jominy *Connexion pour test pédale de validation |
Functional dimensions | Contact unit contact area ** 18x4mmMinimum inside radius of workpiece 25mmMinimum inside Ø of workpiece 400mmMinimum outside radius of workpiece 20mmBasic test surface 200 x 200mm ***Anvil adaption Ø 10mm / Ø 19mm (optional)Max. specimen height (reduced by addiing accessories and X-axis) 250mmX-axis option (optional)Z-axis height (Max. specimen heigh)t 250mmZ-axis height with X-axis added (Max. specimen height) 165mmY-axis range 160mmThroat depth 220mmMax. specimen weight 100kgMax. specimen weight with X-axis mounted 50kgMax. speed Y 48mmMax. speed Z 10mm/sec |
Functionality | 5,7" touch screen display (optional)mm (optional)mm/inch (optional)AVPAK software control (optional)HR unit resolution 0,01Test force range 1-250kg, 9,8-2450NTest force switching by softwareReal time test force controlFully automatic test cycleMotorized test force generationMotorized Z-AxisLED workroom illuminationRS-232C Digimatic, USB2.0 interfaceUSB stick data transfer (optional)Jominy-test capability*Footswitch connection for serial test |
Funkcionális méretek | A csatlakozó egység érintkezési területe ** 18x4mmA munkadarab minimális belső rádiusza 25mmA munkadarab minimális belső átmérője 400mmA munkadarab minimális külső rádiusza 20mmAlap vizsgálati felület 200 x 200mm ***Ülék csatlakozás 10mm / Ø 19mm (választható)Max. mintadarab magasság (csökken a tartozékok magasságával) 250mmX-tengely opció (választható)Z-tengely magasság (Max. mintadarab magasság)t 250mmZ-tengely magassága az X tengely hozzáadásával (Max. mintadarab magasság) 165mmY-tengely tartomány 160mmTorokmélység 220mmMax. mintadarab tömeg 100kgMax. mintadarab súlya felszerelve a X tengelyre 50kgMax. speed Y 48mmMax. speed Z 10mm/sec |
funkcionalitás | 5,7" érintőképernyő (választható)mm (választható)mm/inch (választhatól)AVPAK szoftveres vezérlés (választható)HR egység felbontás 0,01Terhelő erő tatomány 1-250kg, 9,8-2450NTerhelőerő szoftveresen kapcsolhatóValós idejű terhelőerő szabályozásTeljesen automatikus tesztciklusMotoros terhelőerő generálásMotorized Z-tengelyLED munkatér megvilágításRS-232C Digimatic, USB2.0 interfészUSB csatlakozású adatátvitel (választható)Jominy-teszt képesség*Lábkapcsoló csatlakoztatása sorozatméréshez |
Funkcjonalność | 5,7-calowy ekran dotykowy (opcjonalny)mm (opcjonalny)mm/cale (opcjonalny)Sterowanie oprogramowaniem AVPAK (opcjonalnie)Rozdzielczość jednostek HR 0,01Zakres siły testowej 1-250kg, 9,8- 2450NPrzełączanie siły testowej przez oprogramowanieSterowanie siłą testową w czasie rzeczywistymW pełni automatyczny cykl testowyZmotoryzowane generowanie siły testowejZmotoryzowana oś ZOświetlenie robocze LEDRS-232C Digimatic, interfejs USB2.0Transfer danych z pamięci USBMożliwość wykonania testu Jominy*Podłączenie przełącznika nożnego do testu szeregowego |
Funkční rozměry | Contact unit contact area ** 18x4mmMinimum inside radius of workpiece 25mmMinimum inside Ø of workpiece 400mmMinimum outside radius of workpiece 20mmBasic test surface 200 x 200mm ***Anvil adaption Ø 10mm / Ø 19mm (optional)Max. specimen height (reduced by addiing accessories and X-axis) 250mmX-axis option (optional)Z-axis height (Max. specimen heigh)t 250mmZ-axis height with X-axis added (Max. specimen height) 165mmY-axis range 160mmThroat depth 220mmMax. specimen weight 100kgMax. specimen weight with X-axis mounted 50kgMax. speed Y 48mmMax. speed Z 10mm/sec |
Funkčnost | 5.7" dotykový displejmmHR jednotka rozlišení 0,1Zkušební zatížení začínající od 3 do 187,5KG, 29,42- 1839NZkušební zatížení přepínatelné softwarově.Ovládání zkušebního zatížení v reálném čase.Automatické zastavení vřetene a sekvenční zatížení.Manuální vyhodnocovací jednotka.Motorizované zkušební zatížení.LED osvětlení.RS-232C Digimatic, USB2.0 rozhranníPřenos dat přes USB flashku.Kompatibilní s Jominy-zkouškou.*Připojení nožního spínače pro sériovou zkoušku |
Funktionalität | 5,7" touch screen display (optional)mm (optional)mm/inch (optional)AVPAK software control (optional)HR unit resolution 0,01Test force range 1-250kg, 9,8-2450NTest force switching by softwareReal time test force controlFully automatic test cycleMotorized test force generationMotorized Z-AxisLED workroom illuminationRS-232C Digimatic, USB2.0 interfaceUSB stick data transfer (optional)Jominy-test capability*Footswitch connection for serial test |
Funktionelle Dimensionen | Contact unit contact area ** 18x4mmMinimum inside radius of workpiece 25mmMinimum inside Ø of workpiece 400mmMinimum outside radius of workpiece 20mmBasic test surface 200 x 200mm ***Anvil adaption Ø 10mm / Ø 19mm (optional)Max. specimen height (reduced by addiing accessories and X-axis) 250mmX-axis option (optional)Z-axis height (Max. specimen heigh)t 250mmZ-axis height with X-axis added (Max. specimen height) 165mmY-axis range 160mmThroat depth 220mmMax. specimen weight 100kgMax. specimen weight with X-axis mounted 50kgMax. speed Y 48mmMax. speed Z 10mm/sec |
Funktioner | 5,7" touch screen display (optional)mm (optional)mm/inch (optional)AVPAK software control (optional)HR unit resolution 0,01Test force range 1-250kg, 9,8-2450NTest force switching by softwareReal time test force controlFully automatic test cycleMotorized test force generationMotorized Z-AxisLED workroom illuminationRS-232C Digimatic, USB2.0 interfaceUSB stick data transfer (optional)Jominy-test capability*Footswitch connection for serial test |
Funktionsabmessungen | Contact unit contact area ** 18x4mmMinimum inside radius of workpiece 25mmMinimum inside Ø of workpiece 400mmMinimum outside radius of workpiece 20mmBasic test surface 200 x 200mm ***Anvil adaption Ø 10mm / Ø 19mm (optional)Max. specimen height (reduced by addiing accessories and X-axis) 250mmX-axis option (optional)Z-axis height (Max. specimen heigh)t 250mmZ-axis height with X-axis added (Max. specimen height) 165mmY-axis range 160mmThroat depth 220mmMax. specimen weight 100kgMax. specimen weight with X-axis mounted 50kgMax. speed Y 48mmMax. speed Z 10mm/sec |
Funzionalita | 5,7" touch screen display (optional)mm (optional)mm/inch (optional)AVPAK software control (optional)HR unit resolution 0,01Test force range 1-250kg, 9,8-2450NTest force switching by softwareReal time test force controlFully automatic test cycleMotorized test force generationMotorized Z-AxisLED workroom illuminationRS-232C Digimatic, USB2.0 interfaceUSB stick data transfer (optional)Jominy-test capability*Footswitch connection for serial test |
Huvudenhetens dimensioner | External dimensions 428(W) × 837(D) × 935(H) mmExternal dimensions display unit 191(W) × 71(D) × 147(H) mm (optional)Mass main unit 205kgPower supply AC100V, 120V, 220V, 240V Auto-selectionPower cord not includedOperation temperature 5-40 °CHumidity 55-65% (without dew condensation) |
Kogel indrukking plastictest | HB 49N; HB 132N; HB 358N; HB 961N |
Kugeleindruckversuch für Kunststoffe | HB 49N; HB 132N; HB 358N; HB 961N |
Main unit dimensions | External dimensions 428(W) × 837(D) × 935(H) mmExternal dimensions display unit 191(W) × 71(D) × 147(H) mm (optional)Mass main unit 205kgPower supply AC100V, 120V, 220V, 240V Auto-selectionPower cord not includedOperation temperature 5-40 °CHumidity 55-65% (without dew condensation) |
Měření hloubky podle Brinella | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Měření hloubky podle Vickerse | HVD 30; HVD 50 |
Mesure de la profondeur Brinell | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Mesure de profondeur Vickers | HVD 30; HVD 50 |
Méthodes et normes d'essai applicables | Rockwell, Rockwell Superficiel (EN ISO 6508, ASTM E-18, la norme JIS B7726)Essai plastique (EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Essai Rockwell Alpha (ASTM D785 B)Brinell, pénétration seulement (EN ISO 6506, ASTM E-10, norme JIS B7724)HBT (VDE / VDI 2616 - non standard) |
Misura prof. Vickers | HVD 30; HVD 50 |
Misurazione della profondità Brinell | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Möjliga testmetoder och standarder | Rockwell, Rockwell Superficial (EN ISO 6508, ASTM E-18, JIS B7726)Ball indentation test on plastic materials (EN ISO 2039-1)Plastic test (EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Rockwell Alpha test (ASTM D785 B)Brinell, Indentation only (EN ISO 6506, ASTM E-10, JIS B7724)HBT (VDE/VDI 2616 - non standard)HVT (VDE/VDI 2616 - non standard) |
Műanyag Golyós lenyomat teszt | HB 49N; HB 132N; HB 358N; HB 961N |
Műanyag Rockwell α teszt | (HRR) |
Műanyag Rockwell műanyag teszt | HRE; HRL; HRR; HRK; HRM |
Norme e test applicabili | Rockwell, Rockwell Superficial (EN ISO 6508, ASTM E-18, JIS B7726)Ball indentation test on plastic materials (EN ISO 2039-1)Plastic test (EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Rockwell Alpha test (ASTM D785 B)Brinell, Indentation only (EN ISO 6506, ASTM E-10, JIS B7724)HBT (VDE/VDI 2616 - non standard)HVT (VDE/VDI 2616 - non standard) |
Odpowiednie metody badawcze i normy | Rockwell, Rockwell Superficial (EN ISO 6508, ASTM E-18, JIS B7726)Test wgniatania kulki na materiałach plastycznych (EN ISO 2039-1)Testy plastiku (EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Test Rockwell Alpha (ASTM D785 B)Brinell, tylko wgniatanie (EN ISO 6506, ASTM E-10, JIS B7724)HBT (VDE/VDI 2616 - niestandardowe)HVT (VDE/VDI 2616 - niestandardowe) |
Plastica Rockwell α test | (HRR) |
Plastica Rockwell Plastic test | HRE; HRL; HRR; HRK; HRM |
Plastik test α Rockwella | (HRR) |
Plastik Test plastiku Rockwella | HRE; HRL; HRR; HRK; HRM |
Plastik test wgniatania kulki | HB 49N; HB 132N; HB 358N; HB 961N |
Plastique Rockwell test plastique | HRE; HRL; HRR; HRK; HRM |
Plastique test par pénétration | HB 49N; HB 132N; HB 358N; HB 961N |
Plastique Test α Rockwell | (HRR) |
Plastisk Rockwell α test | (HRR) |
Plastisk Rockwell Plastisk test | HRE; HRL; HRR; HRK; HRM |
Pomiar głębokości Brinella | HBD 2.5/62.5; HBD 2.5/187.5; HBD 5/250 |
Pomiar głębokości Vickersa | HVD 30; HVD 50 |
Používané zkušební metody a normy | Rockwell, Rockwell Superficial (EN ISO 6508, ASTM E-18, JIS B7726)Test plastů (EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Rockwell Alpha test (ASTM D785 B)Brinell, pouze vtisk (EN ISO 6506, ASTM E-10, JIS B7724)HBT (VDE/VDI 2616 - nestandardní)HVT (VDE/VDI 2616 - nestandardní) |
Povrchový Rockwell | HR15N; HR15TW; HR15WW; HR15XW; HR15YW; HR30N; HR30TW; HR30WW; HR30XW; HR30YW; HR45N; HR45TW; HR45WW; HR45XW; HR45YW |
Rockwell | HRA; HRF; HRH; HRL; HRR; HRD; HRB; HRE; HRM; HRS; HRC; HRG; HRK; HRP; HRV |
Rockwell Kunststoffprüfung | HRE; HRL; HRR; HRK; HRM |
Rockwell Plastic test | HRE; HRL; HRR; HRK; HRM |
Rockwell Superficial | HR15N; HR15TW; HR15WW; HR15XW; HR15YW; HR30N; HR30TW; HR30WW; HR30XW; HR30YW; HR45N; HR45TW; HR45WW; HR45XW; HR45YW |
Rockwell Superficiale | HR15N; HR15TW; HR15WW; HR15XW; HR15YW; HR30N; HR30TW; HR30WW; HR30XW; HR30YW; HR45N; HR45TW; HR45WW; HR45XW; HR45YW |
Rockwell Superficiel | HR15N; HR15TW; HR15WW; HR15XW; HR15YW; HR30N; HR30TW; HR30WW; HR30XW; HR30YW; HR45N; HR45TW; HR45WW; HR45XW; HR45YW |
Rockwell α Kunststofftest | (HRR) |
Rockwell α plastic test | (HRR) |
Rozměry hlavní jednotky | External dimensions 428(W) × 837(D) × 935(H) mmExternal dimensions display unit 191(W) × 71(D) × 147(H) mm (optional)Mass main unit 205kgPower supply AC100V, 120V, 220V, 240V Auto-selectionPower cord not includedOperation temperature 5-40 °CHumidity 55-65% (without dew condensation) |
Sfera test plastica | HB 49N; HB 132N; HB 358N; HB 961N |
Super Rockwell | HR15N; HR15TW; HR15WW; HR15XW; HR15YW; HR30N; HR30TW; HR30WW; HR30XW; HR30YW; HR45N; HR45TW; HR45WW; HR45XW; HR45YW |
Szuper-Rockwell | HR15N; HR15TW; HR15WW; HR15XW; HR15YW; HR30N; HR30TW; HR30WW; HR30XW; HR30YW; HR45N; HR45TW; HR45WW; HR45XW; HR45YW |
Verfügbare Prüfmethoden und Normen | Rockwell, Rockwell Superficial (DIN EN ISO 6508, ASTM E-18, JIS B7726)Kugeleindruckversuch für Kunststoff (DIN EN ISO 2039-1)Kunststoffprüfung (DIN EN ISO 2039-2, ASTM D785 A, JIS K7202-2)Rockwell Alpha Test (ASTM D785 B)Brinell, nur Eindruck (DIN EN ISO 6506, ASTM E-10, JIS B7724)HBT (VDE/VDI 2616 - nicht genormt)HVT (VDE/VDI 2616 - nicht genormt) |
Vickers Depth Measurement | HVD 30; HVD 50 |
Vickers dieptemeting | HVD 30; HVD 50 |
Vickers mélységmérés | HVD 30; HVD 50 |
Vickers Tiefenmessung | HVD 30; HVD 50 |
Vniková kulička pro zkoušky plastů | HB 49N; HB 132N; HB 358N; HB 961N |
Wymiary funkcjonalne | Powierzchnia styku jednostki kontaktowej ** 18x4mmMinimalny promień wewnętrzny przedmiotu mierzonego 25mmMinimalna wewnętrzna Ø przedmiotu mierzonego 400mmMinimalny promień zewnętrzny przedmiotu mierzonego 20mmPodstawowa powierzchnia testowa 200 x 200mm ***Adaptacja kowadełka Ø 10mm / Ø 19mm (opcjonalnie)Maks. wysokość próbki (zmniejszona przez dodanie akcesoriów i oś X) 250mmopcja osi X (opcjonalnie)wysokość osi Z (maks. wysokość próbki) 250mmWysokość osi z dodaną osią X (maks. wysokość próbki) 165mmZakres osi Y 160mmGłębokość gardła 220mmMaks. waga próbki 100kgMaks. waga próbki z zamontowaną osią X 50kgMaks. prędkość Y 48mmMaks. prędkość Z 10mm/sec |
Wymiary jednostki głównej | Wymiary zewnętrzne 428(szer.) × 837(gł.) × 935(wys.) mmWymiary zewnętrzne wyświetlacza 191(szer.) × 71(gł.) × 147(wys.) mmWaga jednostki głównej 205kgZasilanie AC100V, 120V, 220V, 240V Automatyczny wybórPrzewód zasilający nie jest dołączonyTemperatura pracy 5-40 °CWilgotność 55-65% (bez kondensacji) |
Zkouška plastu podle Rockwella | (HRR) |
- Артикул: 810-526-11
-
Цена по запросу
В сравнение
Доставка
Срок поставки от 2 недель.
— Бесплатная доставка до терминала тк;
— Доставим любым удобным и выгодным для вас способом;
Получить консультацию
+7 (499) 673-00-78
info@imperial-tools.ru
Оплата
— Наличный расчет;
— Без наличный расчет;
— Банковский перевод;